Difference between revisions of "Structure of Config Files"
Tag: visualeditor-switched |
|||
(8 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
− | Configuration files have a simple structure consisting of | + | [[Category: Node Configuration]] |
− | + | [[Category:How to]] | |
− | + | Configuration files have a simple structure consisting of stanzas, key/value pairs and comments. A stanza is a block of text within a configuration file. It starts with a name (or number) surrounded by square brackets on a line by itself. Configuration files will have one or more stanzas. Each stanza continues until the next stanza or end of file. | |
+ | <syntaxhighlight lang="ini"> | ||
+ | [this is a stanza] | ||
+ | ... | ||
− | + | [this is another stanza] | |
+ | ... | ||
+ | </syntaxhighlight> | ||
+ | Stanzas contain one or more ker/value pairs. Key/value pairs set various values within each stanza. | ||
+ | <syntaxhighlight lang="ini">myname=timothy ; There are some who call me Tim?</syntaxhighlight> | ||
− | In this example of two nodes the stanza is the node number and the key/value pairs set the CW ID and the ID timer: | + | Config file comments are preceded with a semicolon. In this example of two nodes the stanza is the node number and the key/value pairs set the CW ID and the ID timer: |
− | < | + | <syntaxhighlight lang="ini"> |
[1998] | [1998] | ||
idrecording = |iW1ABC | idrecording = |iW1ABC | ||
Line 15: | Line 22: | ||
idrecording = |iW1XYZ | idrecording = |iW1XYZ | ||
idtime = 540000 | idtime = 540000 | ||
− | </ | + | </syntaxhighlight> |
==Settings to name other Stanzas== | ==Settings to name other Stanzas== | ||
Line 21: | Line 28: | ||
For example: | For example: | ||
− | < | + | <syntaxhighlight lang="ini"> |
[1000] | [1000] | ||
functions=functionsVHF | functions=functionsVHF | ||
Line 40: | Line 47: | ||
61=autopatchup,noct=1,farenddisconnect=1,dialtime=20000 ; Autopatch up | 61=autopatchup,noct=1,farenddisconnect=1,dialtime=20000 ; Autopatch up | ||
0=autopatchdn ; Autopatch down | 0=autopatchdn ; Autopatch down | ||
− | </ | + | </syntaxhighlight> |
+ | |||
+ | ==Named Stanzas in rpt.conf== | ||
+ | * controlstates= | ||
+ | * functions= | ||
+ | * link_functions= | ||
+ | * macro= | ||
+ | * phone_functions= | ||
+ | * telemetry= | ||
+ | * wait_times= | ||
''Note:'' A stanza is also called a context in Asterisk PBX terminology, particularly related to the dialplan. | ''Note:'' A stanza is also called a context in Asterisk PBX terminology, particularly related to the dialplan. | ||
− |
Latest revision as of 18:50, 27 January 2022
Configuration files have a simple structure consisting of stanzas, key/value pairs and comments. A stanza is a block of text within a configuration file. It starts with a name (or number) surrounded by square brackets on a line by itself. Configuration files will have one or more stanzas. Each stanza continues until the next stanza or end of file.
[this is a stanza]
...
[this is another stanza]
...
Stanzas contain one or more ker/value pairs. Key/value pairs set various values within each stanza.
myname=timothy ; There are some who call me Tim?
Config file comments are preceded with a semicolon. In this example of two nodes the stanza is the node number and the key/value pairs set the CW ID and the ID timer:
[1998]
idrecording = |iW1ABC
idtime = 540000 ; 9 minutes
[1999]
idrecording = |iW1XYZ
idtime = 540000
Settings to name other Stanzas
Some key=value pairs point to other stanzas. This allows nodes on the same server to have the same settings (without duplicate entries) or different settings in some cases. For example the phone patch command may be *6 on one node, yet *61 on another.
For example:
[1000]
functions=functionsVHF
[1001]
functions=functionsVHF ;same functions as node 1000
[1002]
functions=functionsUHF
[functionsVHF]
; Two meter Autopatch up is *6
6=autopatchup,noct=1,farenddisconnect=1,dialtime=20000
0=autopatchdn ; Autopatch down
[functionsUHF]
; 440 Autopatch up is *61
61=autopatchup,noct=1,farenddisconnect=1,dialtime=20000 ; Autopatch up
0=autopatchdn ; Autopatch down
Named Stanzas in rpt.conf
- controlstates=
- functions=
- link_functions=
- macro=
- phone_functions=
- telemetry=
- wait_times=
Note: A stanza is also called a context in Asterisk PBX terminology, particularly related to the dialplan.