Line 1: Line 1:  +
[[Category:How to]]
 +
[[Category:Node Configuration]]
 
= MDC-1200 =
 
= MDC-1200 =
 
+
[https://en.wikipedia.org/wiki/MDC-1200 MDC-1200]<ref>[https://en.wikipedia.org/wiki/MDC-1200 MDC-1200]</ref> support has been available as a compile time option since app_rpt 0.225 and is now enabled by default.
[https://en.wikipedia.org/wiki/MDC-1200 MDC-1200] support has been avialble as a compile time option since app_rpt 0.225 and is now enabled by default.
      
== MDC-1200 decoding display ==
 
== MDC-1200 decoding display ==
   
On the CLI when MDC-1200 is received the following will be displayed:
 
On the CLI when MDC-1200 is received the following will be displayed:
   Line 64: Line 64:  
Put an [mdcmacro] clause in rpt.conf
 
Put an [mdcmacro] clause in rpt.conf
   −
<pre>
+
<syntaxhighlight lang="ini">
 
IXXXX=*something        ; will match PTTID XXXX
 
IXXXX=*something        ; will match PTTID XXXX
   Line 72: Line 72:     
CXXXX-YYYY=*something  ; will match unit XXXX calling unit YYYY
 
CXXXX-YYYY=*something  ; will match unit XXXX calling unit YYYY
</pre>
+
</syntaxhighlight>
 +
 
 +
The character '%' may be used to match any single character and '*' may be used to match any number of characters.
   −
The character '%' may be used to match any single character
  −
and '*' may be used to match any number of characters.
   
For example:
 
For example:
<pre>
+
<syntaxhighlight lang="ini">
 
E*=*something  ; would match ANY ID with an emergency
 
E*=*something  ; would match ANY ID with an emergency
</pre>
+
</syntaxhighlight>Note that if you have a macro setup to do something based on ID it will execute once if it hears the ID multiple times in a row (ie during testing).  If you are testing a macro based on unit ID such as:
 +
<syntaxhighlight lang="ini">[mdcmacro]
 +
I1701=*81#</syntaxhighlight>
 +
This will announce the time only once if there are no other MDC ID's received between hearing ID 1701.
    
== MDC-1200 Encoding ==
 
== MDC-1200 Encoding ==
    
MDC-1200 bursts maybe sent from macros or the commpand line via cop,60:
 
MDC-1200 bursts maybe sent from macros or the commpand line via cop,60:
<pre>
+
<syntaxhighlight lang="ini">
 
function_code=cop,60,type,UnitID[,DestID,SubCode]
 
function_code=cop,60,type,UnitID[,DestID,SubCode]
</pre>
+
</syntaxhighlight>
    
  Type is 'I' for PttID, 'E' for Emergency, and 'C' for Call
 
  Type is 'I' for PttID, 'E' for Emergency, and 'C' for Call
Line 104: Line 107:     
For example in a macro:
 
For example in a macro:
<pre>
+
<syntaxhighlight lang="ini">8765=cop,60,I,1234                    ; send MDC PTTID 1234
8765=cop,60,I,1234                    ; send MDC PTTID 1234
+
8766=cop,60,C,1600,1701,8015          ; Send MDC1200 call burst using unitID 1600, DestID 1701, and Maxtrac Selective call Subcode</syntaxhighlight>
8766=cop,60,C,1600,1701,8015          ; Send MDC1200 call burst using unitID 1600, DestID 1701, and Maxtrac Selective call Subcode
  −
</pre>
      
From the command line sending a unit call to a CDM1550 unit 1701 from unit 1600:
 
From the command line sending a unit call to a CDM1550 unit 1701 from unit 1600:
<pre>
+
<syntaxhighlight lang="sh">rpt cmd 41618 cop 60 C,1600,1701,8205</syntaxhighlight>
rpt cmd 41618 cop 60 C,1600,1701,8205
+
 
</pre>
+
=References=
 +