Changes

Jump to navigation Jump to search
no edit summary
Line 1: Line 1:  +
The following information is about transmitting tone sequences using COP functions in rpt.conf.
 +
 +
=== COP function ===
 +
Cop function 48 is associated with transmitting arbitrary tone sequences. These tone sequences can be any combination of single tones, dual tones, and silence periods,
 +
 +
These tone sequences are only heard on the repeater transmitter and not sent over the network.
 +
 +
This function is available in app_rpt.c version 0.183 or later.
 +
 +
=== Tone Sequences ===
 +
Tone sequences are specified as <code>!Tone_A+Tone_B/Duration_in_MS</code>. ToneB is optional and not specified, the + operator must be omitted.
 +
 +
The exclamation point operator is required when specifying arbitrary tones.
 +
 +
DTMF tones can be entered in shorthand fashion as as single digits separated by commas.
 +
 +
=== Examples ===
 +
881=cop,48,1,2,3,4,#                                          ; Send DTMF 1,2,3,4, and #
 +
882=cop,48,!399.8/1000,!339.6/2000                            ; Send two tone paging sequence: Motorola codes 144,141
 +
883=cop,48,!1100+1700/100,!0/60,!700+900/60,!0/60,!700+1100/60,!0/60,!700+900/60,!0/60,!1500+1700/60 ; Send MF tone sequence KP121ST
 
[[Category:How to]]
 
[[Category:How to]]